Remote Control Operation
Bulk
Command:
Consol.
Response:
Status
Where 'pn' is the last parameter returned.
Parameter
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
B–38
<add/BCS_'cr'
>add/BCS_p1,p2,p3, . . . pn'cr''lf']
Parameter Name
(Command Reference)
Modulator RF output
(ref. 'RF_' command).
Modulator IF frequency
(ref. 'MF_' command).
Modulator rate
(ref. 'MR_' command).
Modulator preset 'A' assignment
(ref. 'ARMA_' command).
Modulator preset 'B' assignment
(ref. 'ARMB_' command).
Modulator preset 'C' assignment
(ref. 'ARMC_' command).
Modulator preset 'D'
(ref. 'ARMD_' command).
Modulator preset 'V' assignment
(ref. 'ARMV_' command).
Modulator power offset
(ref. 'MPO_' command).
Modulator output power level
(ref. 'MOP_' command).
Scrambler enable
(ref. 'SE_' command).
Differential encoder enable
(ref. 'DENC_' command).
Modulator type
(ref. 'MT_' command).
Modulator encoder type
(ref. 'MET_' command).
Carrier only mode ON/OFF.
Demodulator IF
(ref. 'DF_' command).
This command causes bulk modem status to be returned.
To reduce the length of the response, message parameter
data are returned without identifiers. However, parameter
identification can be determined by order of return. Each
status parameter is terminated with a ',' (comma) except for
the last parameter which has the standard message
termination sequence ('cr''lf']). Most of the data returned is
formatted the same way as the single command status
request (refer to the appropriate portions of this document in
preceding sections). Additional configuration status of new
options and features will always be appended to the end.
Description
p1 = n, where 'n' is '0' (off) or '1' (on).
p2 = nnn.nnnnnn, IF frequency in MHz.
p3 = nnnn_mmmm.mmm, code rate/data rate in kbit/s.
p4 = nnnn_mmmm.mmm, code rate/data rate in kbit/s.
p5 = nnnn_mmmm.mmm, code rate/data rate in kbit/s.
p6 = nnnn_mmmm.mmm, code rate/data rate in kbit/s.
p7 = nnnn_mmmm.mmm, code rate/data rate in kbit/s.
p8 = nnnn_mmmm.mmm, code rate/data rate in kbit/s.
p9 = snn.n, modulator power offset in dB.
p10 = snn.n, transmitter output power level in dBm.
p11 = n, where 'n' is '0' (off) or '1' (on).
p12 = n, where 'n' is '0' (off) or '1' (on).
p13 = n, where 'n' is '0' (EFD), '1' (INTL), '3' (FDC), '4'
(CSC), or '6' (SDM51).
p14 = n, where 'n' is '0' ( SEQ), '1' (VIT).
p15 = n, where 'n' is '0' (off) or '1' (on).
p16 = nnn.nnnnnn, demodulator IF frequency in MHz.
SDM-300A Satellite Modem
Rev. 4