8.2 Monitoring Machine Operation Status and Signal Waveforms
8.2.1 Using the SigmaWin+
8.2
Monitoring Machine Operation Status and Signal Waveforms
To monitor waveforms, use the SigmaWin+ trace function or a measuring instrument, such as a
memory recorder.
8.2.1
Using the SigmaWin+
This section describes how to trace data and I/O with the SigmaWin+.
Refer to the following manual for detailed operating procedures for the SigmaWin+.
AC Servo Drive Engineering Tool SigmaWin+ Operation Manual (Manual No.: SIET S800001 34)
Operating Procedure
1.
Click the
maWin+.
2.
Select Trace in the Menu Dialog Box.
The Trace Dialog Box will be displayed.
Trace Objects
You can trace the following items.
• Data Tracing
• Torque Reference
• Feedback Speed
• Reference Speed
• Position Reference Speed
• Position Error (Deviation)
• Position Amplifier Error (Deviation)
• Motor - Load Position Deviation
• Speed Feedforward
• Torque Feedforward
8-4
Servo Drive Button in the workspace of the Main Window of the Sig-
Trace Objects
• Effective (Active) Gain
• Main Circuit DC Voltage
• External Encoder Speed
• Control Mode
• Amount of Quadrant Projection Correc-
• Clearance Offset Reference
• Gap
Click this button to display the Trace Setting
Dialog Box shown below, and set the data to
trace and the trace conditions.
tion