YASKAWA SGD7S series Product Manual page 84

Sigma-7s servopack with ft/ex specification for cutting application feed shaft motor
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

15.
Click the Writing Results Button.
 Identified Moment of Inertia Ratio Box
The moment of inertia ratio that was found with operation and measurements is dis-
played here.
 Writing Results Button
If you click this button, Pn103 (Moment of Inertia Ratio) in the SERVOPACK is set to the
value that is displayed for the identified moment of inertia ratio.
 Pn103: Moment of Inertia Ratio Box
The value that is set for the parameter is displayed here.
After you click the Writing Results Button, the value that was found with operation and
measurements will be displayed as the new setting.
 Back Button
This button is disabled.
 Cancel Button
This button will return you to the Tuning Dialog Box.
16.
Confirm that the Identified Moment of Inertia Ratio Box and the Pn103: Moment of
Inertia Ratio Box show the same value and then click the Finish Button.
17.
Click the OK Button.
18.
Click the Execute Button.
If the setting of the moment of inertia ratio (Pn103) was changed, the new value will be saved and the
Tuning Dialog Box will be displayed again.
This concludes the procedure to estimate the moment of inertia ratio.
5.4 Estimating the Moment of Inertia
5.4.4 Operating Procedure