YASKAWA SGD7S series Product Manual page 282

Sigma-7s servopack with ft/ex specification for cutting application feed shaft motor
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

11.1 Corresponding SERVOPACK and SigmaWin+ Function Names
11.1.2 Corresponding SERVOPACK Monitor Display Function Names
Menu Bar
Button
Motion
Monitor
Status
Monitor
Input Sig-
nal Moni-
tor
Output
Signal
Monitor
Service
Life Moni-
tor
Product
Informa-
tion
*1.
You can use Un010 to monitor the upper limit setting for the maximum motor speed or the upper limit setting for
the encoder output resolution.
You can monitor the upper limit of the encoder output resolution setting (Pn281) for the current maximum motor
speed setting (Pn385), or you can monitor the upper limit of the maximum motor speed setting for the current
encoder output resolution setting.
Select which signal to monitor with Pn080 = n.X (Calculation Method for Maximum Speed or Encoder
Output Pulses).
• If Pn080 = n.0, the encoder output resolution (Pn281) that can be set is displayed.
• If Pn080 = n.1, the maximum motor speed (Pn385) that can be set is displayed in mm/s.
*2.
This applies to the following motors. The display will show 0 for all other models.
SGM7J, SGM7A, SGM7P, SGM7G, and SGMCV
11-4
SigmaWin+
Name [Unit]
Power Consumption [W]
Consumed Power [0.001 Wh]
Cumulative Power Consumption
[Wh]
Absolute Encoder Multiturn Data
Position within One Rotation of
Absolute Encoder [encoder pulses]
Lower Bits of Absolute Encoder
Position [encoder pulses]
Upper Bits of Absolute Encoder
Position [encoder pulses]
Clearance Offset Reference (Input)
[Reference Unit]
Gap (Output) [Reference Unit]
Gap (Output) [AD Value]
Polarity Sensor Signal Monitor
Active Gain Monitor
Safety I/O Signal Monitor
Input Signal Monitor
Output Signal Monitor
Installation Environment Monitor −
SERVOPACK
Installation Environment Monitor −
*2
Servomotor
Service Life Prediction Monitor −
Built-in Fan
Service Life Prediction Monitor −
Capacitor
Service Life Prediction Monitor −
Surge Prevention Circuit
Service Life Prediction Monitor −
Dynamic Brake Circuit
Motor − Resolution
Continued from previous page.
SERVOPACK
Un No.
Un032
Power Consumption [W]
Un033
Consumed Power [0.001 Wh]
Un034
Cumulative Power Consumption [Wh]
Un040
Absolute Encoder Multiturn Data
Position within One Rotation of Absolute
Un041
Encoder [encoder pulses]
Lower Bits of Absolute Encoder Position
Un042
[encoder pulses]
Upper Bits of Absolute Encoder Position
Un043
[encoder pulses]
Clearance Offset Reference (Input) [Reference
Un114
Unit]
Un115
Gap (Output) [Reference Unit]
Un116
Gap (Output) [AD Value]
Un011
Polarity Sensor Signal Monitor
Effective Gain Monitor (gain settings 1 = 1, gain
Un014
settings 2 = 2)
Un015
Safety I/O Signal Monitor
Un005
Input Signal Monitor
Un006
Output Signal Monitor
SERVOPACK Installation Environment Monitor
Un025
[%]
Servomotor Installation Environment Monitor
*2
Un026
[%]
Un027
Built-in Fan Remaining Life Ratio [%]
Un028
Capacitor Remaining Life Ratio [%]
Surge Prevention Circuit Remaining Life Ratio
Un029
[%]
Un02A
Dynamic Brake Circuit Remaining Life Ratio [%]
Linear Encoder Pitch (Scale pitch = Un084 ×
Un084
Un085
10
[pm])
Linear Encoder Pitch Exponent (Scale pitch =
Un085
Un084 × 10
Un085
Un020
Rated Motor Speed [min
Un021
Maximum Motor Speed [min
Name [Unit]
[pm])
-1
]
-1
]