10.1 List of Servo Parameters
10.1.2 List of Servo Parameters
Parameter
No.
Pn008
Pn00A
10-8
Name
Application Function
2
Selections 8
Low Battery Voltage Alarm/Warning Selection
n.
X
0
Output alarm (A.830) for low battery voltage.
1
Output warning (A.930) for low battery voltage.
Function Selection for Undervoltage
0
Do not detect undervoltage.
n.
X
1
Detect undervoltage warning and limit torque at host controller.
Detect undervoltage warning and limit torque with Pn424 and
2
Pn425 (i.e., only in SERVOPACK).
Warning Detection Selection
n.
X
0
Detect warnings.
1
Do not detect warnings except for A.971.
n.X
Reserved parameter (Do not change.)
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.
n.
X
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.
Stopping Method for Forced Stops
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.
n.
X
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000 to
–
4000
7121
0000 to
–
0001
0044
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
Rotary
Setup
restart
Reference
Reference
Reference
page 9-40
After
All
Setup
restart
Reference
Reference
Continued on next page.
Refer-
ence
–
*1
*1
–
*1
*1