YASKAWA SGD7S series Product Manual page 152

Sigma-7s servopack with ft/ex specification for cutting application feed shaft motor
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

• Gain Adjustment
Tool
Digital Operator
Fn00D
Setup - Analog Monitor Out-
SigmaWin+
put Adjustment
 Operating Procedure
Use the following procedure to adjust the analog monitor output.
1.
Click the
Servo Drive Button in the workspace of the Main Window of the Sig-
maWin+.
2.
Select Adjust the Analog Monitor Output in the Menu Dialog Box.
The Adjust the Analog Monitor Output Dialog Box will be displayed.
3.
Click the Zero Adjustment or Gain Adjustment Tab.
4.
While watching the analog monitor, use the +1 and -1 Buttons to adjust the offset.
There are two channels: CH1 and CH2. If necessary, click the down arrow on the Channel Box and
select the channel.
This concludes adjusting the analog monitor output.
8.2 Monitoring Machine Operation Status and Signal Waveforms
Function
Σ-7-Series Digital Operator Operating Manual
(Manual No.: SIEP S800001 33)
8.2.2 Using a Measuring Instrument
Operating Procedure Reference
Operating Procedure on page 8-9
8
8-9