10.1 List of Servo Parameters
10.1.2 List of Servo Parameters
Parameter
No.
Pn006
10-6
Name
Application Function
2
Selections 6
Analog Monitor 1 Signal Selection
Motor speed (1 V/1,000 min
00
Motor speed (1 V/1,000 mm/s)
Speed reference (1 V/1,000 min
01
Speed reference (1 V/1,000 mm/s)
Torque reference (1 V/100% rated torque)
02
Force reference (1 V/100% rated force)
03
Position deviation (0.05 V/reference unit)
Position amplifier deviation (after electronic gear) (0.05 V/encoder pulse unit)
04
Position amplifier deviation (after electronic gear) (0.05 V/linear encoder
pulse unit)
Position reference speed (1 V/1,000 min
05
Position reference speed (1 V/1,000 mm/s)
06
Reserved setting (Do not use.)
07
Load-motor position deviation (0.01 V/reference unit)
Positioning completion (positioning completed: 5 V, positioning not com-
08
pleted: 0 V)

n.
XX
Speed feedforward (1 V/1,000 min
09
Speed feedforward (1 V/1,000 mm/s)
Torque feedforward (1 V/100% rated torque)
0A
Force feedforward (1 V/100% rated force)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V, 3rd gain: 3 V, 4th gain: 4 V)
Completion of position reference distribution (completed: 5 V, not com-
0C
pleted: 0 V)
0D
External encoder speed (1 V/1,000 min
0E
Reserved setting (Do not use.)
0F
Reserved setting (Do not use.)
10
Main circuit DC voltage
11 to 33
Reserved setting (Do not use.)
Difference between clearance offset reference and gap (0.05 V/1 reference
34
unit)
35
Gap (0.01 V/1 reference unit)
36 to 46
Reserved setting (Do not use.)
47
Quadrant projection correction amount (1 V/100% rated torque)
48 to 5F
Reserved setting (Do not use.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000 to
0002
105F
-1
)
-1
)
-1
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
All
Setup
ately
-1
)
)
-1
: value at the motor shaft)
Continued on next page.
Refer-
ence
page
8-5

Advertisement

Table of Contents
loading

Table of Contents