10.1 List of Servo Parameters
10.1.2 List of Servo Parameters
Parameter
No.
Pn868
*8
M3
Pn869
*8
M3
Pn880
Pn881
Pn882
Pn883
10-44
Name
SVCMD_IO Output Sig-
2
nal Monitor Allocations
1
Output Signal Monitor Allocation for CN1-1 and CN1-2 (SVCMD_IO)
0
Allocate bit 24 (IO_STS1) to CN1-1/CN1-2 output signal monitor.
1
Allocate bit 25 (IO_STS2) to CN1-1/CN1-2 output signal monitor.
2
Allocate bit 26 (IO_STS3) to CN1-1/CN1-2 output signal monitor.

n.
X
3
Allocate bit 27 (IO_STS4) to CN1-1/CN1-2 output signal monitor.
4
Allocate bit 28 (IO_STS5) to CN1-1/CN1-2 output signal monitor.
5
Allocate bit 29 (IO_STS6) to CN1-1/CN1-2 output signal monitor.
6
Allocate bit 30 (IO_STS7) to CN1-1/CN1-2 output signal monitor.
7
Allocate bit 31 (IO_STS8) to CN1-1/CN1-2 output signal monitor.
CN1-1/CN1-2 Output Signal Monitor Enable/Disable Selection

n.
X
0
Disable allocation for CN1-1/CN1-2 output signal monitor.
1
Enable allocation for CN1-1/CN1-2 output signal monitor.
Output Signal Monitor Allocation for CN1-23 and CN1-24 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-1/CN1-2 allocations.
CN1-23/CN1-24 Output Signal Monitor Enable/Disable Selection

n.X
0
Disable allocation for CN1-23/CN1-24 output signal monitor.
1
Enable allocation for CN1-23/CN1-24 output signal monitor.
SVCMD_IO Output Sig-
2
nal Monitor Allocations
2
Output Signal Monitor Allocation for CN1-25 and CN1-26 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-1/CN1-2 allocations.
CN1-25/CN1-26 Output Signal Monitor Enable/Disable Selection

n.
X
0
Disable allocation for CN1-25/CN1-26 output signal monitor.
1
Enable allocation for CN1-25/CN1-26 output signal monitor.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Station Address Moni-
2
tor (for maintenance,
read only)
Set Transmission Byte
Count Monitor [bytes]
2
(for maintenance, read
only)
Transmission Cycle Set-
ting Monitor [× 0.25 μs]
2
(for maintenance, read
only)
Communications Cycle
Setting Monitor [trans-
2
mission cycles] (for
maintenance, read only)
Setting
Setting
Default
Range
Unit
Setting
0000 to
0000
1717
0000 to
0000
1717
03 to EF
0
17, 32, 48
0
0 to FFFF
0
0 to 32
0
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
*2
*2