YASKAWA SGD7S series Product Manual page 190

Sigma-7s servopack with ft/ex specification for cutting application feed shaft motor
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
A timeout error
A.Ed1:
occurred for a
Command Exe-
MECHATROLINK
cution Timeout
command.
The three-phase
power supply wiring is
not correct.
The three-phase
power supply is
A.F10:
unbalanced.
Power Supply
Line Open Phase
A single-phase power
(The voltage was
supply was input with-
low for more than
out specifying a sig-
one second for
nal-phase AC power
phase R, S, or T
supply input (Pn00B =
when the main
n.1).
power supply
was ON.)
A failure occurred in
the SERVOPACK.
A.F50:
A failure occurred in
Servomotor Main
the SERVOPACK.
Circuit Cable Dis-
connection
(The Servomotor
did not operate or
power was not
supplied to the
The wiring is not cor-
Servomotor even
rect or there is a faulty
though the
contact in the motor
SV_ON (Servo
wiring.
ON) command
was input when
the Servomotor
was ready to
receive it.)
Confirmation
Execute the SV_ON or
Check the motor status
SENS_ON command only
when the command is
when the motor is not
executed.
operating.
• For fully-closed loop
control, check the
status of the external
encoder when the
Execute the SENS_ON
command is exe-
command only when an
cuted.
external encoder (e.g., a
• For other types of
linear encoder) is con-
control, check the
nected.
status of the linear
encoder when the
command is exe-
cuted.
Check the power sup-
Make sure that the power
ply wiring.
supply is correctly wired.
Measure the voltage for
each phase of the
Balance the power sup-
three-phase power sup-
ply by changing phases.
ply.
Check the power sup-
Match the parameter set-
ply and the parameter
ting to the power supply.
setting.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
Make sure that the Servo-
Check the wiring.
motor is correctly wired.
9.1 Alarm Displays
9.1.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
*1
*1
*1
Continued on next page.
9
9-37