YASKAWA SGD7S series Product Manual page 207

Sigma-7s servopack with ft/ex specification for cutting application feed shaft motor
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

9.3 Troubleshooting Based on the Operation and Conditions of the Servomotor
Problem
Absolute
Encoder
Position
Deviation
Error (The
position
that was
saved in the
host con-
troller when
the power
was turned
OFF is dif-
ferent from
the posi-
tion when
the power
was next
turned ON.)
9-54
Possible Cause
Noise interference occurred
because of incorrect Encoder
Cable specifications.
Noise interference occurred
because the Encoder Cable
is too long.
Noise interference occurred
because the Encoder Cable
is damaged.
Replace the Encoder Cable
and correct the cable instal-
lation environment.
There is variation in the FG
potential because of the
influence of machines on the
Servomotor side, such as a
welder.
There is a SERVOPACK
pulse counting error due to
noise.
The encoder was subjected
to excessive vibration or
shock.
A failure occurred in the
encoder.
A failure occurred in the SER-
VOPACK.
Confirmation
Check the Encoder Cable
to see if it satisfies speci-
fications. Use shielded
twisted-pair cables or
screened twisted-pair
cables with conductors of
2
at least 0.12 mm
(stranded wire).
Check the length of the
Encoder Cable.
Check the Encoder Cable
to see if it is pinched or
the sheath is damaged.
Check to see if the
Encoder Cable is bundled
with a high-current line or
installed near a high-cur-
rent line.
Check to see if the
machines are correctly
grounded.
Check to see if there is
noise interference on the
I/O signal line from the
encoder or Serial Con-
verter Unit.
Check to see if vibration
from the machine
occurred.
Check the Servomotor
installation (mounting sur-
face precision, securing
state, and alignment).
Check the linear encoder
installation (mounting sur-
face precision and secur-
ing method).
Continued from previous page.
Correction
Reference
Use cables that satisfy
the specifications.
• Rotary Servomotors:
The Encoder Cable
length must be 50 m
max.
• Linear Servomotors:
Make sure that the
Serial Converter Unit
cable is no longer
than 20 m and that
the Linear Encoder
Cable and the Sensor
Cable are no longer
than 15 m each.
Replace the Encoder
Cable and correct the
cable installation envi-
ronment.
Correct the cable lay-
out so that no surge is
applied by high-current
lines.
Properly ground the
machines to separate
them from the FG of
the encoder.
Implement counter-
measures against noise
for the encoder or
Serial Converter Unit
wiring.
Reduce machine vibra-
tion. Improve the
mounting state of the
Servomotor or linear
encoder.
Replace the Servomo-
tor or linear encoder.
Replace the SERVO-
PACK.
Continued on next page.

Advertisement

Table of Contents
loading

Table of Contents