6 Multicast Route Management
l
Data Preparation
To set the parameters for controlling the multicast routing policy, you need the following data.
No.
1
2
3
4
6.7.2 Setting the Maximum Number of Entities in the Multicast
Forwarding Table
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
multicast forwarding-table route-limit limit
The maximum number of entities in the multicast forwarding table is set.
By default, the maximum number of entities in the multicast forwarding table is 4096.
----End
6.7.3 Setting the Maximum Number of Downstream Nodes of a
Multicast Forwarding Entity
6-12
Configuring basic multicast functions
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Quidway S9300 Terabit Routing Switch
Configuration Guide - Multicast
Data
Addresses, masks (or mask lengths) of the
multicast source and multicast group
Matching policy, sequence, and preference of
multicast routes
Maximum number of routes in the multicast
forwarding table
Maximum number of downstream nodes of
each routing entity in the multicast
forwarding table
Issue 01 (2009-07-28)