4 PIM-SM Configuration

4.13.2 Enabling PIM BFD

Context
Do as follows on the two S9300s between which the PIM neighbor relation is established.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface vlanif vlan-id
The VLANIF interface view is displayed.
This command can be run only on VLANIF interfaces of an S9300. The vlan-id parameter
identifies a VLAN. The ID of a VLANIF interface must match an existing VLAN.
Step 3 Run:
pim bfd enable
PIM BFD is enabled.
By default, PIM BFD is disabled.
----End

4.13.3 (Optional) Changing Values of the BFD Detection Parameter

Context
Do as follows on the two S9300s between which the PIM neighbor relation is established.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface vlanif vlan-id
The VLANIF interface view is displayed.
The command can be run only on the VLANIF interface of the S9300. The vlan-id parameter
specifies the ID of a VLAN. The ID of a VLANIF interface must match an existing VLAN.
Step 3 Run: