Buffer Register And Multi-Active Register - YASKAWA yasnac i80m Instruction Manual

Cnc system for machining centers
Table of Contents

Advertisement

2.2
PROGRAMMING
(Cont'd)
Buffer Register and Multi-active Register
2.2.3
Buffer register
(1)
During normal operation,
two
blocks of data
are
read in advance and
offset
computing
is made for the follow-on
operation.
(2)
In the tool radius
compensation C-ÿmode,
two
blocks of data
or up
to
4
blocks of data
are
read in advance and compensation
computing
required for
the
next
operation
is executed.
(3)
One block
can
contain
up to
128 characters including
EOB.
Multi-active
Registerÿ
(1)
For the portion of
part
programs
sandwiched between M93 and M92,
up to
7 blocks of data are read in advance.
Table 2.2.9
Meaning
M code
Multi-active
register
OFF
M92
Multi-active
register
ON
M93
(2)
Inter-block
stoppage
can
be eliminated when the
program
is
so made
that the automatic
operation
time of advance reading of 7
blocks is
longer than processing
time of advance
reading
of-
next
7 blocks of
data.
Advance
reading
is
not
made for
every
7
blocks but is
always ready
to
be made
up
to
7 blocks
in M93
mode.
-