Automatic Correction Sensor (Das) Cleaning - MIMAKI UJV100-160 Care And Maintenance

Hide thumbs Also See for UJV100-160:
Table of Contents

Advertisement

4
Clean the UV-LED lamp.
• Wipe off any ink adhering using a cleaning stick moistened with maintenance liquid. Wipe off the
maintenance liquid. Make sure none remains.
5
Clean around the print head.
• Wipe off any ink and dust adhering using a cleaning stick moistened with maintenance liquid. Wipe
off the maintenance liquid. Make sure none remains.
Clean the print head sides (dark red area)
using a cleaning stick.
Clean using a cleaning stick or soft cloth.
• Never touch the print head nozzle surface.
6
Once cleaning is complete, close the cover, then press the [ENTER] key.

Automatic Correction Sensor (DAS) Cleaning

The DAS sensor is located on the carriage underside. If dust or debris accumulates on the sensor, an error
may occur in the automatic correction function (Automatic correction of drop position).
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
• The carriage moves to the maintenance space.
Never touch the nozzle
surface!