Sign In
Upload
Manuals
Brands
ADEMCO Manuals
Security System
Vista-2000
ADEMCO Vista-2000 Manuals
Manuals and User Guides for ADEMCO Vista-2000. We have
2
ADEMCO Vista-2000 manuals available for free PDF download: Installation Instructions Manual, Programming Manual
ADEMCO Vista-2000 Installation Instructions Manual (88 pages)
Brand:
ADEMCO
| Category:
Security System
| Size: 1.6 MB
Table of Contents
Table of Contents
3
General Description
9
Installing the Control
11
Mounting the Cabinet
11
Installing the Lock (if Used)
11
Installing the Control's Circuit Board Alone or (if Used), with a 4204 Relay Unit
11
Figure 1. Installing the Cabinet Lock
11
Figure 2. Installing the PC Board Alone, or (if Used), with a 4204 Relay Unit
12
Figure 3. Installing the PC Board & RF Receiver Together in the Cabinet
12
Installing Control and RF Receiver Circuit Boards Together in the Cabinet
13
Standard Phone Line Connections
13
Figure 4. Standard Telephone Line Connections
13
Wiring the AC Transformer
14
Installing the Back-Up Battery
14
Earth Ground Connections
14
Installing Remote Keypads
15
Keypads that May be Used
15
Wiring to the Keypads
15
Wiring Run Chart for Devices Drawing aux Power from the Control
15
Mounting the Keypads
16
Using a Supplementary Power Supply to Power Additional Keypads
16
Figure 5. Keypad Connections to the Control Board
16
Preliminary Check-Out Procedure
17
Figure 6. Using a Supplementary Power Supply for Keypads
17
Basic Hard-Wired Zones 1-6
18
Installing the Hard-Wired Zones
18
Common Characteristics for Zones 1-6
18
Wiring Burglary and Panic Devices to Zones 1-6
18
Wiring 4-Wire Smoke/Combustion Detectors on Zones 5
18
Figure 7. 4-Wire Smoke Detector Connections to Zone 5
18
Compatible 4-Wire Smoke/Combustion Detectors
19
Programming Hard-Wired Zones
19
Programming Panic Keys
20
Check-Out Procedure for Hard-Wired Zones 1-6
21
Wireless (Rf) Zone Expansion (5700 & 5800 Rf Systems)
22
Wireless Systems Available
22
Wireless System Operation and Transmitter Supervision
22
Transmitter Battery Life
23
Receiver Supervision
23
Installation and Setup of the 4281/5881 Series Wireless Receivers
23
Installing the 5800TM Module
24
5700 Series Transmitter Setup
24
Figure 8. 4281, 5881, and 5882 Wireless Receivers (Cover Removed)
24
Setting the DIP Switches on 5700 Series Wireless Transmitters
25
Wireless Zone/ID Assignments for 5700 Series Transmitters
25
DIP Switch Tables for 5700 RF System Wireless Devices
26
Compatible 5700 Series Transmitters
27
Programming the Control for a 5700 Wireless System
28
Using the House ID Sniffer Mode (5700 Systems)
28
Zone Programming for 5700 Series Transmitters
28
Go/Nogo Test
30
5800 Series Transmitter Setup
31
5800 Series Transmitter Input Loops
31
5800 Series Transmitter Input Types
31
Compatible 5800 Series Transmitters
32
Programming the RF Transmitters (5800 RF Systems)
33
Enrolling 5800 Transmitters into the System
34
Enrolling through Zone Programming ( 56)
34
To Either Temporarily or Permanently Remove a Zone from the System (5800 System)
37
Deleting a Transmitter Serial Number from a Zone in 56 Mode (5800 System)
37
Check-Out Procedure for Wireless Zones
37
Transmitter ID Sniffer Mode (5700 RF Systems Only)
37
Go/No Go Test Mode (5700 and 5800 RF Systems)
37
Relay Output Devices
39
Relay Device Basics
39
4204 Relay Modules
39
4204 Setup
39
Supervision
39
Programming Options Defined
39
Figure 9. 4204 Connections to Control
39
Programming Output Relays
41
Example of Output Relay Programming
43
4285 Phone Module
44
Installing the Phone Module
44
General Information
44
Mounting the Phone Module
44
Phone Module Wiring
44
Caller ID Units
45
Figure 10. 4285 Phone Module Wiring Connections
46
Programming the Control for Phone Access
47
Checking the Operation of the 4285 Phone Module
48
External Sounders
49
Compatible Sounders
49
Sounder Connections
50
Programming for External Sounders
50
Testing the Sounder
50
Figure 11. Typical Sounder Wiring
50
Long Range Radio
51
General Information
51
Connection
51
Programming for Long Range Radio
51
Figure 12. Long Range Radio Connections
51
Audio Alarm Verification (Aav) Unit
52
General Information
52
Wiring Connections
52
Programming
52
Figure 13. Connection of AAV Unit When Not Using a 4285 Phone Module
53
Figure 14. Connection of AAV Unit When also Using a 4285 Phone Module
53
Final Power up
54
Earth Ground Connections
54
AC Power-Up
54
Connecting the Back-Up Battery
54
Calculating the Battery Size Needed
54
Making the Battery Connections
55
Auxiliary Device Current Draw Worksheet
55
Alpha Descriptor Programming
56
Assigning Zone Descriptors
56
Entering Zone Descriptors (in Program Menu Mode 82)
56
Programming the Descriptors
56
Alternate Method for Programming Zone Descriptors
58
Adding Custom Words
59
Alpha Vocabulary List (for Entering Zone Descriptors)
60
Character (ASCII) Chart
60
Sequential Mode
61
(For 5800 Series Wireless Transmitters)
61
System Communication
64
Report Code Formats
64
Table of Contact ID Event Codes
66
Communication Programming
66
Testing the System
71
Test Procedure
71
To the Installer
72
System Operation
73
Security Codes
73
Installer Code
73
Assigning the Master Code
73
Changing the Master Code
73
User Codes
73
Duress Code
73
Keypad Functions
74
General Information
74
Arming Functions
74
Panic Keys
75
4285 Phone Module (if Used)
75
Relays Outputs (if Used)
75
Exit Alarm Displays (if Programmed)
75
Trouble Conditions
76
General Information
76
Check" and "Battery" Displays
76
Power Failure
76
Other Displays
76
Troubleshooting Guide
77
Contacting Technical Support
79
Specifications & Accessories
80
Specifications
80
Accessories (Compatible Devices)
82
Regulatory Agency Statements
83
Limitations of this Alarm System
86
Limited Warranty
88
Advertisement
ADEMCO Vista-2000 Programming Manual (24 pages)
Brand:
ADEMCO
| Category:
Security System
| Size: 1.12 MB
Table of Contents
Table of Contents
2
Programming Form
3
Mechanics of Programming
7
General Programming Information
7
Entering the Programming Mode
7
Programming a Data Field
8
Reviewing a Data Field/Erasing an Entry in a Data Field
8
Interactive Menu Mode Programming
8
Loading Factory Defaults
8
Programming System Setup Fields
8
Exiting the Programming Mode
8
5800 Series Transmitter Input Loop Identification
9
Alpha Vocabulary List (for Entering Zone Descriptors)
10
Character (ASCII) Chart (for Adding Custom Words)
10
Zone Response Type Definitions
11
Data Field Descriptions
13
Remote Programming and Control (Downloading)
20
General Information
20
Equipment Required
20
Initial Download
20
Remote Programming Information
20
Remote Programming Advisory Notes
21
Summary of Connections Diagram
23
Advertisement
Related Products
Ademco VISTA-20HWse
ADEMCO VISTA-20P Series
ADEMCO VISTA-20PS
ADEMCO VISTA-20SE
Ademco Vista-20
ADEMCO Vista-20HW
ADEMCO VISTA-20PCN
ADEMCO VISTA-20PSCN
ADEMCO VISTA-20SEA
ADEMCO VISTA-25
ADEMCO Categories
Security System
Security Sensors
Keypad
Transmitter
Smoke Alarm
More ADEMCO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL