Summary Of Connections - ADEMCO VIA-30Pse Installation Instructions Manual

Hide thumbs Also See for VIA-30Pse:
Table of Contents

Advertisement

GEL LEAD ACID TYPE.
DO NOT USE GATES BATTERY.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.
BLACK
BATTERY
CHARGING
12V, 4AH
+
VOLTAGE
RED
(e.g. ADEMCO
13.8VDC
No. 467)
OR 12V, 1.2AH
CONNECTOR TABS
USE UL LISTED LIMITED
ENERGY CABLE FOR
1
2
ALL CONNECTIONS
TO 110VAC
UNSWITCHED
OUTLET (24HR)
PLUG-IN
TRANSFORMER
16.5VAC, 25VA
(e.g. ADEMCO
No. 1321.
FOR COMPLETE
USE No. 1321CN
INFORMATION,
IN CANADA)
SEE INSTRUCTIONS
+
ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)
STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE
ADEMCO No. 740 SOUNDER,
No.702 OR 719 SIREN, OR 12V BELL)
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM
HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED
ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING
JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE
CONNECTED TO A POLICE EMERGENCY NUMBER.
ALARM DEVICE MANUFACTURING CO.
A DIVISION OF PITTWAY CORPORATION
165 Eileen Way, Syosset, New York 11791
N8372V1 4/97
Copyright
©
1997 PITTWAY CORPORATION
BATTERY FUSE
(e.g. ADEMCO No. 90-12)
FOR REPLACEMENT
USE SAME VALUE
3A
+
BLK
RED
GRN
YEL
3
4
5
6
7
8
+
AUX. POWER
OUTPUT
10.5-13.8VDC
500mA MAX.
INTERRUPTS
FOR FIRE
TRANSMITTER MODULE
ALARM RESET
NOTE:
Wireless Bidirectional Keypad)
KEYPAD
CURRENT
No. 4285 VOICE MODULE
MUST BE
INCLUDED
IN AUX.
CURRENT
MAY ALSO BE CONNECTED.
DRAIN
SEE INSTRUCTIONS ACCOM-
CALCULATIONS
PANYING THOSE DEVICES.
REMOTE
KEYPAD
REMOTE KEYPADS
SYSTEM MUST BE
PROGRAMMED WITH A
No. 5137AD OR 6139. IT NEED
NOT REMAIN IN SYSTEM.
AFTER PROGRAMMING,
THE SYSTEM CAN USE:
No. 4127(20mA), 4137AD (60mA),
5137AD (90mA), 6127 (20mA),
6128 (30mA), 6137 (85mA),
6138 (100mA), OR 6139 (100mA).
MULTIPLE KEYPADS MAY BE
USED, BUT USE MAX. OF 220 FT.
OF #22 WIRE OR 550 FT. OF #18.
ADEMCO No. 4219
WIRED EXPANSION MODULE
(8 ADD'L EOLR WIRED ZONES)
-OR-
ADEMCO No. 4229
WIRED EXPANSION/RELAY MODULE
(8 ADD'L EOLR WIRED ZONES PLUS 2
BLK
OUTPUT RELAYS)
RED
-OR-
GRN
ADEMCO No. 4204 RELAY MODULE
YEL
(4 OUTPUT RELAYS)
AND/OR
ADEMCO 4281 or 5881 Type
RF RECEIVER
WIRELESS ZONES
BLK
4281L:
UP TO 4
RED
4281M/5881L:
UP TO 8
GRN
5881M:
UP TO 16
YEL
4281/5881H:
UP TO 30
9
10
11
12
13
NOT USED
(ZONES 1-4 NOT PRESENT)
OPTIONAL:
No. 5800TM
(20mA)
(for No. 5827BD
AND/OR
(160mA)
AND/OR
No. 7720ECP
LONG RANGE RADIO
• MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 5, 6: 300-500MSEC
• ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE.
SEE DIAGRAM.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
WARNING:
OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED.
WEEKLY TESTING IS REQUIRED TO
ENSURE PROPER OPERATION OF
THIS SYSTEM.
SET UNIT'S DIP SWITCH
FOR DEVICE ADDRESS
OF "1".
See unit's instructions.
AUX PWR
+
5
OUTPUT
-
TERMS
4
+
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
SET RECEIVER'S
DIP SWITCH FOR
DEVICE ADDRESS
TO HI SIDE OF SELECTED ZONE
+
OF "0".
See receiver's
HEAT
TO ZONE 5*
*
ZONES 2–7
instructions.
DETECTOR
-
TO LO SIDE OF SELECTED ZONE
*
IF PROGRAMMED FOR FIRE
14
15
16
17
18
19
TIP
RING
TIP
(BROWN)
(GRAY)
(GREEN)
HANDSET
INCOMING
TELEPHONE WIRING
(VIA RJ31X* JACK DIRECT
CONNECT CORD)
*IN CANADA, CA38A JACK
DOC LOAD NO.: 3
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
AT TELCO JACK BEFORE
1000
1000
OHMS
OHMS
SERVICING THIS UNIT.
EOLR
EOLR
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION'S STANDARD 74
(NATIONAL FIRE PROTECTION ASSOC.,
BATTERYMARCH PARK, QUINCY, MA 02269).
PRINTED INFORMATION DESCRIBING PROPER
INSTALLATION, OPERATION, TESTING,
MAINTENANCE, EVACUATION PLANNING AND
REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
VIA-30P

SUMMARY OF CONNECTIONS

+
RED
BLK
EOL
POWER
SUPER-
-
VISION
VIOLET
RELAY
MODULE
A77-716B
1000
OHMS
EOLR
EARTH
GROUND
TERMINAL
20
21
LOCATED AT
LOWER RIGHT
RING
OF CIRCUIT
(RED)
BOARD
PHONE
LINE
EARTH
GROUND
SEE INSTRUCTIONS
FOR
PROPER GROUNDING
SE

Advertisement

Table of Contents
loading

Table of Contents