Zone Response Type Definitions (Under Field *56) - ADEMCO Via 30+ Installation Instructions Manual

Hide thumbs Also See for Via 30+:
Table of Contents

Advertisement

ZONE
ASSIGNMENT/
ALARM
REPORT
CODES,
etc.
(*56)
Enter Zn Num.
(00=Quit)
20
Zone 20 entered T
Zn ZT - RC
In: L
20 09 - 10
FF: -
4 Zone Number
20 Zone Type
Perimeter
03
Zone Type T
*56
ZONE
ASSIGNMENT/ALARM
REPORT
CODES
(and RF Input ID Learning
for 5800 System)
REFER TO THE ZONE ASSIGNMENT TABLE FOR THIS FIELD
ON THE CENTERFOLD PROGRAMMING FORM
This field is used to program zone numbers, zone types, alarm and report
codes, and to identify the type of loop input device. This field can also be
used for "learning" 5800 series transmitter 1D codes and for entering al-
pha descriptors for zones.
Zone Number (Zn): Upon entering field *56, enter the zone number
that you wish to program (or [0][0] to leave zone programming).
Press [*]. A summary display will come up, showing the status of that
zone's program.
If it is programmed satisfactorily, press [#] to back up one step and enter
another zone number, if desired.
If the zone is not programmed, or you want to change it, press [*]. A
prompt for Zone Type will appear.
Zone Type (ZT): Each zone must be assigned to a zone type, which
defines the way in which the system responds to faults in that zone.
Enter the zone type code (or change it, if necessary). Zone types are
defined below.
ZONE RESPONSE
TYPE DEFINITIONS
Zone
Not Used
Entry/ExitBurglary
Perimeter
Burglary
Interior, Follower
it
Trouble
by Day/
Alarm
by Night
Zone Type 02 is not used in this system.
Program a zone with this zone type if the zone is not used.
This zone type provides entry delay whenever the zone is faulted if the control is
armed in the Away or Stay modes. When the panel is armed in the Instant or
Maximum modes, no entry delay is provided. Exit delay begins whenever the
control is armed, regardless of the arming mode selected. These delays are
programmable. Thi
i
sign
sensors
or
doors through which primary entry and exit will take place.
This zone type gives an instant alarm if the zone is faulted when the panel is
armed in the Away, Stay, Instant or Maximum modes. This zone type is usually
ign
ll
sensors
or
n
rior
doors
and windows.
This zone type is active when the panel is armed in the Away or Maximum modes.
Entry delay (using the programmed entry time) results if the panel is armed in the
Away mode and the entry/exit zone is faulted first. Otherwise this zone type gives
an instant alarm. Exit delay is present for any arming mode. This zone type is
lly
assign
n
vering
an ar
uch
foyer,
lob
r_hallw:
through which one must pass (upon entry, after faulting the entry/exit zone) to
reach the console to disarm the system. Since this zone type is designed to pro-
vide an instant alarm if the entry/exit zone is not violated first, it will protect an area
in the event an intruder hides on the premises prior to the system being armed, or
gains access to the premises through an unprotected area. This zone type is
bypassed
automatically when
the panel is armed
Stay or Instant.
This zone type will give an instant alarm if faulted when armed in the Away, Stay,
Instant or Maximum (night) modes.
During the disarmed state (day), the system
will provide a latched trouble sounding from the console (and a central station
report, if desired). This zone type is usually assigned to a zone which contains a
a]
This zone type can
also be used on a sensor or contact in an area where immediate notification of an
entry is desired.
-—20-