[C1A0] LCF end fence motor abnormality
Is the LCF end fence motor working? (Perform the output check: 03-207)
|
NO
1) Check if the connector of the LCF end fence motor is disconnected.
|
2) Check if any of the connectors CN100, CN101 and CN103 on the LCF
|
|
3) Check if the connector CN344 on the LGC board is disconnected.
|
4) Check if the connector pins are disconnected or the harnesses are open
|
|
5) Check if the conductor patterns on the LCF board and LGC board are short
|
|
6) Replace the LCF end fence motor.
|
7) Replace the LCF board.
|
8) Replace the LGC board.
|
YES
Are the LCF end fence home/stop position sensors working?
(Perform the input check: 03-[FAX]OFF/[5]/[A], /[5]/[B])
|
NO
1) Check if the connectors of the sensors are disconnected.
|
2) Check if either of the connectors CN100 or CN107 on the LCF board is dis-
|
|
3) Check if the connector CN344 on the LGC board is disconnected.
|
4) Check if the slit reaches the sensors.
|
5) Check if the connector pins are disconnected or the harnesses are open
|
|
6) Check if the conductor patterns on the LCF board and LGC board are short
|
|
7) Replace the sensors.
|
8) Replace the LCF board.
|
|
9) Replace the LGC board.
YES
1) Check if the conductor pattern on the LGC board is short circuited or open circuited.
2) Replace the LGC board.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
board is disconnected.
circuited.
circuited or open circuited.
connected.
circuited.
circuited or open circuited.
5 - 57
e-STUDIO281c/351c/451c
TROUBLESHOOTING
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio351cE-studio451c

Table of Contents