Classifi-
Code
cation
553
Image
Drum temperature correc-
control
tion control
554
Image
Image quality open-loop
control
control/Contrast voltage
initial value
555
Image
Drum life correction of
control
laser power initial value
556
Image
Image quality closed-loop
control
control/Contrast voltage
557
Image
Image quality closed-loop
control
control/Laser power
558
Image
Contrast voltage/Correc-
control
tion gain environment set-
ting
559
Image
Image quality closed-loop
control
control automatic start-up/
At power-ON
560
Imagel
Process switching for
image smoothing (Text/
Photo)
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Func-
<Accept-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
ALL
(color)
PPC
(black)
2 - 123
Default
RAM
Contents
able
value>
1
M
Sets whether or not cor-
<0-1>
recting the drum volt-
age depending on the
drum surface tempera-
ture in open-loop con-
trol.
0: Invalid
1: Valid
1
M
Sets whether or not
<0-1>
deciding the initial value
of contrast voltage in
open-loop control.
0: Invalid
1: Valid
1
M
Sets whether or not cor-
<0-1>
recting the laser power
depending on the drum
life when the laser
power initial value is set
in open-loop control.
0: Invalid
1: Valid
1
M
Sets whether or not cor-
<0-1>
recting the contrast volt-
age in closed-loop
control.
0: Invalid
1: Valid
1
M
Sets whether or not cor-
<0-1>
recting the laser power
in closed-loop control.
0: Invalid
1: Valid
1
M
Sets whether or not
<0-1>
switching the correc-
tion amount once at
contrast voltage correc-
tion depending on the
environment.
0: Invalid
1: Valid
1
M
Sets whether perform-
<0-2>
ing closed-loop control
automatically at power-
ON when the fuser
roller temperature
becomes below the
specified level.
0: Invalid
1: Valid (at mode 1)
2: Valid (at mode 2)
1
M
Sets whether or not
<0-1>
performing a smooth-
ing process (primary
scanning direction,
2,400 dpi or equiva-
lent).
0: Invalid
1: Valid
ERROR CODE AND SELF-DIAGNOSTIC MODE