4.2

General Descriptions for PM Procedure

(1)
Preparation
Ask the user about the current conditions of the equipment and note them down.
Before starting maintenance, make some sample copies and store them.
See the replacement record and check the parts to be replaced in the PM support mode (6S-
2) or list printing mode (9S-103).
6S-2
: [6] + [START] + [POWER] ON
9S-103 : [9] + [START] + [POWER] ON
PM SUPPORT CODE LIST
XX-XX-'XX 11:28
UNIT
DRUM
DRUM BLADE
DRUM BRUSH
GRID
MAIN CHARGER WIRE
WIRE CLEANING PAD
Turn OFF the power and make sure to unplug the equipment.
(2)
Perform a preventive maintenance using the following checklist and illustrations. Refer to the
Service Manual if necessary.
(3)
Plug in the equipment after the maintenance has been finished. Then turn ON the power and
make some copies to confirm that the equipment is working properly.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
[2]
[103]
OUTPUT PAGES/
PM OUTPUT PAGE/
DEVELOP COUNTS DEVELOP COUNTS
22220
200000
22220
200000
22220
200000
22220
200000
22220
200000
22220
200000
Fig. 4-7
4 - 9
[START]
[START]
DRIVE COUNTS
PM DRIVE COUNTS
30948
320000
30948
320000
30948
320000
30948
320000
30948
320000
30948
320000
e-STUDIO281c/351c/451c