(4)
Move the returning roller shaft to its lower
limit (the slack of a belt is lightly taken); then,
tighten the screw on the tension arm plate.
(5)
Check to make sure that the returning roller
shaft moves smoothly.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Screw
Tension arm
plate
Fig. 3-77
Fig. 3-78
3 - 83
Returning
roller shaft
Returning
roller shaft
e-STUDIO281c/351c/451c
ADJUSTMENT
3