Toner Density Control Related Service Call; Toner Density Detection Voltage Abnormality - Toshiba e-STUDIO281c Service Handbook

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO281c:
Table of Contents

Advertisement

5.1.19

Toner density control related service call

[CF20] Toner density detection voltage abnormality
(1)
Specify the developer unit with the abnormality by checking the setting values of 08-824-0 to 08-
824-2. (When the value is "1", an abnormality occurs.)
(2)
Correct the defective section of the unit specified in (1) with the following procedure.
Is the developer material transported properly?
Is the form of magnetic brush is normal?
|
NO
1) Check if the amount of the developer material is normal or any foreign matter
|
|
2) Correct the transport mechanism of developer material.
|
3) Check the polar position and correct if necessary.
YES
Is the color auto-toner sensor stained?
YES
Clean it.
NO
Is the color auto-toner sensor shutter solenoid working normally?
(Perform the output check: 03-125/175)
Is the color auto-toner sensor working?
|
NO
1) Check if the connectors or joint connectors of the color auto-toner sensor
|
|
2) Check if the connector CN332 on the LGC board is disconnected.
|
3) Check if the connector pins are disconnected or the harnesses are open cir-
|
|
4) Replace the color auto-toner sensor shutter solenoid.
|
5) Check if the conductor pattern on the LGC board is short circuited or open
|
|
6) Replace the LGC board.
|
7) Replace the color auto-toner sensor and perform "Enforced correction of
|
|
|
YES
Is the color auto-toner sensor shutter opening position correct?
(Perform the output check: 03-125/175)
|
NO
Adjust the install position of solenoid so that the sensor holder will touch and
|
face the positioning component when opening the shutter.
YES
1) Check if the conductor pattern on the LGC board is short circuited or open circuited.
2) Replace the LGC board.
(3)
When the correction is completed, reset the values of 08-824-0 to 08-824-2 from "1" to "0" to
clear the abnormality.
e-STUDIO281c/351c/451c
TROUBLESHOOTING
is mixed in.
shutter solenoid and color auto-toner sensor are disconnected.
cuited.
circuited.
color auto-toner sensor light amount (05-208)".
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved