Toshiba e-STUDIO281c Service Handbook page 147

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO281c:
Table of Contents

Advertisement

Classifi-
Code
cation
569
Image
Image quality closed-loop
control
control automatic start-up/
Temperature setting of
fuser roller at power-ON
570
Image
Image quality closed-loop
control
control automatic start-up/
Relative humidity differ-
ence setting
571
Image
Image quality closed-loop
control
control automatic start-up/
Setting of period of time
unattended
572
Image
Image quality closed-loop
control
control automatic start-up/
Setting of accumulated
print volume
573
Image
Abnormality detection
control
count (Y)
Display/0 clearing
574
Image
Abnormality detection
control
count (M)
Display/0 clearing
575
Image
Abnormality detection
control
count (C)
Display/0 clearing
576
Image
Abnormality detection
control
count (K)
Display/0 clearing
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Func-
<Accept-
Items
tion
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
ALL
ALL
ALL
2 - 125
Default
RAM
Contents
able
value>
8
M
Sets the fuser roller
<0-20>
temperature to perform
closed-loop control
when "1" or "2" (valid) is
set in 08-559.
0: 20°C 1: 25°C
2: 30°C 3: 35°C
4: 40°C 5: 45°C
6: 50°C 7: 55°C
8: 60°C 9: 65°C
10: 70°C 11: 75°C
12: 80°C 13: 85°C
14: 90°C 15: 95°C
16: 100°C 17: 105°C
18: 110°C 19: 115°C
20: 120°C
4
M
Sets the relative humid-
<0-6>
ity difference to per-
form the closed-loop
control when "1" or "2"
(valid) is set in 08-565.
0: 0%
2: 10%
4: 20%
6: 30%
4
M
Sets the period of time
<0-24>
unattended to perform
closed-loop control
when "1" or "2" (valid) is
set in 08-566.
Setting value x 1 (hour)
10
M
Sets the number of
<0-30>
accumulated print vol-
ume to perform closed-
loop control when "1" or
"2" (valid) is set in 08-
567.
Setting value x 100
(pages)
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
0
M
Counts the abnormality
<0-16>
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
ERROR CODE AND SELF-DIAGNOSTIC MODE
Pro-
cedur
e
1
1
1: 5%
3: 15%
5: 25%
1
1
1
1
1
1
e-STUDIO281c/351c/451c