[F]

Secondary scanning data laser writing start position

This adjustment has to be performed for each paper source.
The following table shows the order of the paper source to be adjusted, code, paper size and accept-
able values.
Order for
Paper
adjustment
source
1
Lower
drawer
2
Upper
drawer
3
PFP or LCF
4
Bypass feed
5
Duplexing
While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
Press [1] ([3] for duplexing) → [FAX]. (A grid pattern with 10 mm squares is printed out.)
(2)
(3)
Measure the distance D from the leading edge of the paper to the 6th line of the grid pattern.
* Normally, the 1st line of the grid pattern is not printed.
* At the duplexing, measure it on the top side of the grid pattern.
(4)
Check if the distance D is within 52±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance D again.
<Procedure>
(Adjustment Mode) → (Key in the code shown above) → [START]
→ (Key in an acceptable value shown above)
→ [ENTER] or [INTERRUPT] (Stored in memory)
→ "100% A" is displayed
→ Press [1] ([3] for duplexing)
→ [FAX] → (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance D becomes (approx. 0.2 mm/step).
[G] Primary scanning data laser writing start position at duplexing
Note:
Note:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
[G-1]

Adjustment for long-sized paper

While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
Press [3] → [FAX]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from the lower
(2)
drawer.)
(3)
Check the grid pattern on the test print and measure the distance E from the left edge of the
paper to the 6th line of the grid pattern.
(4)
Check if the distance E is within 52±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance E again.
<Procedure>
(Adjustment Mode) → (Key in the code [498]) → [START] → [0] → [START]
→ (Key in a value (acceptable values: 0 to 255))
→ [ENTER] or [INTERRUPT] (Stored in memory)
→ "100% A" is displayed.
→ Press [3] → [FAX] → (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance E becomes (approx. 0.04 mm/
step).
e-STUDIO281c/351c/451c
ADJUSTMENT
Code
Paper size
441
A3/LD
440
A4/LT
444/443
A4/LT
442
A4/LT
445
A3/LD
3 - 12
Acceptable
value
0 to 80
0 to 40
0 to 40
0 to 40
0 to 40
Paper fed from the lower drawer