3.16 Adjustment of LCF (MP-4004)
3.16.1
Sheet sideways deviation adjustment
When the center of the printed image shifts to the front side or rear side, adjust the tray position taking
the following procedure.
<Procedure>
(1)
Pull out the tray unit.
(2)
Loosen 3 screws and move the adjustment board to the right position. Then screw it shut.
•
The center of the printed image shifts to the front side:
Move the adjustment board to the front side (Arrow (B) in the upper figure).
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
A
B
Adjustment board
Fig. 3-95
[ Rear ]
Feeding direction
[ Front ]
Fig. 3-96
3 - 87
Center
e-STUDIO520/523/600/603/720/723/850/853
ADJUSTMENT
3