Code to be used for the adjustment

Code
Classifi-
cation
499
Develop
Black developer unit
-ment
lift up/down timing
adjustment
Note:
Note:
Do not input more than 8 for acceptable value. (If a number from 9 to 255 is input, it is processed
as 8.)
Relation between adjustment value and changing amount
Adjustment
value
0
Turning 32 degrees CW (approx. 12 mm in the lever circumference)
1
Turning 24 degrees CW (approx. 9 mm in the lever circumference)
2
Turning 16 degrees CW (approx. 6 mm in the lever circumference)
3
Turning 8 degrees CW (approx. 3 mm in the lever circumference)
4
Default value
5
Turning 8 degrees CCW (approx. 3 mm in the lever circumference)
6
Turning 16 degrees CCW (approx. 6 mm in the lever circumference)
7
Turning 24 degrees CCW (approx. 9 mm in the lever circumference)
8
Turning 32 degrees CCW (approx. 12 mm in the lever circumference)
* CW: Clockwise
CCW: Counter Clockwise
e-STUDIO281c/351c/451c
ADJUSTMENT
Adjustment mode (05)
Items
Function
ALL
Changing amount for default value
(Turning degree of black developer unit lift up/down lever)
3 - 62
05/07
Default
RAM
<Accept-
able
value>
4
M
Changes the lift up/down
<0-255>
timing of the black devel-
oper unit when a CEB0
error occurs.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved