[C] Confirmation of the error
"Back Up ERROR X" (X: Error number) is displayed at the top of the LCD screen when the data have
not been properly backed up / restored. In this case, turn the power OFF and then check the following
items. After confirming and solving the problem, back up / restore the data again from the beginning.
•
Does the USB storage device meet the conditions being used for this cloning?
•
Is the updated program file written on the USB storage device properly?
•
Is the USB storage device installed properly?
•
Is the USB storage device or the equipment damaged?
Error number
ERROR 1
ERROR 2
ERROR 3
ERROR 4
ERROR 5
ERROR 6
ERROR 7
ERROR 8
ERROR 9
ERROR 10
ERROR 11
e-STUDIO281c/351c/451c
DATA CLONING with USB STORAGE DEVICE
Fig. 9-35
Error content
Copy error
I/F error
USB memory full error
Working folder error
File not found error
Security error
Checksum error
Model check error
Version check error
Destination check error
Serial number check error