[C150] PFP upper drawer tray abnormality
[C160] PFP lower drawer tray abnormality
Does the tray go up? (Perform the output check: 03-278, 280)
|
NO
1) Check if the connector of the tray-up motor is disconnected.
|
2) Check if any of the connectors CN241, CN242 and CN244 on the PFP
|
|
3) Check if the connector CN344 on the LGC board is disconnected.
|
4) Check if the connector pins are disconnected or the harnesses are open
|
|
5) Check if the conductor patterns on the PFP board and LGC board are short
|
|
6) Replace the tray-up motor.
|
7) Replace the PFP board.
|
8) Replace the LGC board.
|
YES
Is the tray-up sensor working? (Perform the input check: 03-[FAX]OFF/[2]/[H], /[4]/[H])
|
NO
1) Check if the connector of the sensor is disconnected.
|
2) Check if any of the connectors CN241, CN247 and CN248 on the PFP
|
|
3) Check if the connector CN344 on the LGC board is disconnected.
|
4) Check if the slit reaches the sensor.
|
5) Check if the connector pins are disconnected or the harnesses are open
|
|
6) Check if the conductor patterns on the PFP board and LGC board are short
|
|
7) Replace the tray-up sensor.
|
8) Replace the PFP board.
|
|
9) Replace the LGC board.
YES
1) Check if the conductor pattern on the LGC board is short circuited or open circuited.
2) Replace the LGC board.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
board is disconnected.
circuited.
circuited or open circuited.
board is disconnected.
circuited.
circuited or open circuited.
5 - 55
e-STUDIO281c/351c/451c
TROUBLESHOOTING
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio351cE-studio451c

Table of Contents