12)White banding (at right angles to feeding direction)

Cause/Section
Step
Main charger
1
Is there foreign matter on the charger?
2
Is the terminal contact poor?
Drum
3
Is there any abnormalities on the drum
surface?
4
Is the drum grounded?
Discharge lamp
5
Is the discharge lamp lighting properly?
Developer unit
6
Is the developer sleeve rotating correctly?
Is there any abnormalities on the sleeve
surface?
7
Is the connection of developer bias supply
terminal normal?
Drive systems
8
Is the drum, scanner or transfer belt jit-
tery?
High-voltage
9
Is the high-voltage transformer output
transformer
defective?
(main charger
wire/grid, 1st/
2nd transfer
roller and devel-
oper bias)
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Fig. 5-12
Check items
5 - 127
Measures
Remove foreign matter.
Clean or adjust the terminals.
Replace the drum.
Check the contact of the grounding plate.
Replace the discharge lamp or clean ter-
minals.
Check the developer drive system, or
clean the sleeve surface.
Correct it.
Check each drive system.
Check/correct any electric leakage and
related circuits.
If the high-voltage transformer does not
work, replace it.