Classifi-
Code
cation
820-0
Develop-
Color auto-
ment
toner sensor
output
820-1
display for
developer
820-2
material
821
Develop-
ON/OFF of the mode for
ment
developer material stabili-
zation
822-0
Develop-
Number of
ment
times the
mode for
822-1
developer
material stabi-
822-2
lization is per-
formed
823-0
Develop-
Color auto-
ment
toner sensor/
light amount
correction
823-1
voltage abnor-
mal detection
823-2
824-0
Develop-
Color auto-
ment
toner sensor/
toner density
824-1
detection volt-
age abnormal
824-2
detection
849
Fuser
Fusing control switching for
TWD and SAD models
858-0
Develop-
Color toner
ment
forced supply
level display
858-1
858-2
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Func-
<Accept-
Items
tion
Y
ALL
(color)
<0-1023>
M
ALL
(color)
<0-1023>
C
ALL
(color)
<0-1023>
ALL
(color)
Y
ALL
(color)
M
ALL
(color)
C
ALL
(color)
Y
ALL
(color)
M
ALL
(color)
C
ALL
(color)
Y
ALL
(color)
M
ALL
(color)
C
ALL
(color)
ALL
TWD and
TWD and
Y
ALL
(color)
M
ALL
(color)
C
ALL
(color)
2 - 141
Default
RAM
Contents
able
value>
-
M
Displays the output
value of the color auto-
toner sensor to the
-
M
sleeve in color printing.
-
M
0
M
Sets whether or not
<0-1>
performing an aging to
stabilize the status of
developer material
when the toner density
is uneven or the toner
charging amount is low-
ered.
0: ON
1: OFF
0
M
Displays the number of
<0-255>
times the developer
material stabilization is
0
M
performed.
<0-255>
0
M
<0-255>
0
M
Displays "1" when the
<0-1>
abnormal output volt-
age is detected for the
color auto-toner sensor
0
M
light amount correction.
<0-1>
([CF40] error)
0: Normal
0
M
1: Abnormality
<0-1>
detected
0
M
Displays "1" when the
<0-1>
abnormal toner density
detection voltage is
0
M
detected. ([CF20] error)
<0-1>
0: Normal
0
M
1: Abnormality
<0-1>
detected
Other
M
than
SAD: 0
SAD: 1
<0-1>
0
M
Becomes "1" when the
<0-1>
toner density decreases
and it is judged forced
0
M
toner supply is needed.
<0-1>
0: Normal level
0
M
1: Forced supply level
<0-1>
ERROR CODE AND SELF-DIAGNOSTIC MODE