Average pixel count (%) and latest pixel count (%)
There are 2 types of the value calculated as the pixel count, average pixel count (%) and latest
pixel count (%).
Average pixel count (%)
The average value of all pixel count data after each reference data is cleared is calculated and
displayed.
Latest pixel count (%)
The value is displayed for printing just before the pixel counter is confirmed.
-

Type of calculated data

Since this is multifunctional and color equipment, the data of pixel count is calculated for each
function and color.
The following list is the information that can be confirmed by LCD screen. But actually, more
information can be confirmed by the setting mode (08).
See after-mentioned "5)-Display in the setting mode (08)" for details.
Toner cartridge reference
Yellow
Copier function
Printer function
FAX function
-
Total
-

Setting related with the pixel counter function

Standard paper size setting
The standard paper size (A4 or LT) to convert it into the pixel count is selected (08-1500).
Pixel counter display setting
Whether or not to display the pixel counter on the LCD screen is selected (08-1504).
Display reference setting
The reference when displaying the pixel counter on the LCD screen (toner cartridge reference or
service technician reference) is selected (08-1505).

Determination counter of toner empty

This is the counter to determine the replacement of new toner cartridge after the toner empty is
detected.
After the toner empty is detected by the auto-toner sensor, this counter checks if toner empty is
not detected one more time while the specified number of pixel count or output pages is counted.

Pixel counter clearing

There are 3 types for the pixel count clear as follows:
08-1501: All information related to the pixel count is cleared.
08-1502: All information related to the service technician reference pixel count is cleared.
08-1503: All information related to the toner cartridge reference pixel count is cleared.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Magen
Cyan
Black
ta
-
-
Table 2-201 Type of calculated data
2 - 225
06/08
Service technician reference
Full color/Twin color
Magen
Total
Yellow
ta
-
-
-
ERROR CODE AND SELF-DIAGNOSTIC MODE
: With data
: Without data
Black
Cyan
Black
-
-
e-STUDIO281c/351c/451c
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio351cE-studio451c

Table of Contents