Toshiba e-STUDIO281c Service Handbook page 363

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO281c:
Table of Contents

Advertisement

(5)
Press the [Button1] to adjust the alignment position.
Every time the [Button1] is pressed, the alignment plate shifts 1 step (0.419 mm/step) toward the
"+ "direction. (The gap between the alignment plates becomes narrower.)
Adjustment range is from -5 to +5 steps.
If the [Button1] is pressed when the alignment position is at the "+5 step", the plate will return to
the home position and then moves to the position of "-5 step".
(6)
When the adjustment is completed, press the [Button2] on the finisher control panel to store the
adjustment value in memory.
When the value is stored normally, the [LED1] on the control panel will blink for a number of times
that corresponds to the adjustment value set for the equipment.
See the following table for the number of times the [LED1] blinks and its corresponding adjust-
ment value.
(7)
Turn OFF the power of the equipment.
(8)
Turn OFF all bits of the SW1 on the Finisher control board.
(9)
Install the board access cover.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
LED3
LED2
Button1
Fig. 3-95
Number of Blinking
1
2
3
4
5
6
7
8
9
10
11
3 - 97
06/08
LED1
Button2
Adjustment Value
-5
-4
-3
-2
-1
0
+1
+2
+3
+4
+5