Black Banding/Black Streaking In Vertical Direction; Thin Vertical Line (With Color) (Refer To Figure 6-2D.); Thin Vertical Line (Without Color) (Refer To Figure 6-2F.); Periodic Abnormality (Refer To Figure 6-2E.) - Toshiba e-STUDIO477S Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO477S:
Table of Contents

Advertisement

6.5.5.(4) Black banding/black streaking in vertical direction

(4-1) Thin vertical line (with color) (Refer to Figure 6-2D.)

Check item
(4-1-1) ID unit condition
Filming of the ID unit
Is print attempted without toner?

(4-2) Thin vertical line (without color) (Refer to Figure 6-2F.)

Check item
(4-2-1) LED head condition
LED head
Is any foreign material attached on the light
emitting surface of the cell fox lens of the LED
head?
(4-2-2) Condition of paper running path
Paper running path
Check that any burr that may scatter the un-
fused toner on the paper running path does not
exist.
45387101TH Rev.1
Action to be taken
Check work
at NG
Replace toner
cartridge with
new one. If
replacement
does not solve
the problem,
replace the
ID unit. If any
attempt of using
new ID unit as
a trial is going
to be made,
be sure to use
the System
Maintenance
Menu FUSE
KEEP MODE.
Action to be taken
Check work
at NG
Remove the
foreign material.
Remove the
burr.

6.5.5.(5) Periodic abnormality (Refer to Figure 6-2E.)

(5-1) Periodic abnormality occurs in vertical direction

Check item
(5-1-1) Cycle
Image drum
Check that the cycle is 94.3 mm.
Developing roller
Check that the cycle is 39.7 mm.
Toner feed roller
Check that the cycle is 66.6 mm or 72.8mm.
Charge roller
Check that the cycle is 37.7 mm.
Heat roller
Check that the cycle is 90.3mm.
Fuser belt
Check that the cycle is 94.3 mm.
Transfer roller
Check that the cycle is 51.5 mm.
6. Troubleshooting and repair procedure
Action to be taken
Check work
at NG
Replace the ID
unit
Replace the ID
unit
Replace the ID
unit
Replace the ID
unit
Replace the
fuser unit.
Replace the
fuser unit.
Replace the
Transfer Roller.
If any attempt
of using new
consumable
item as a trial
is going to be
made, be sure to
use the System
Maintenance
Menu FUSE
KEEP MODE.
6-51 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio527s

Table of Contents