UltraNet Edge 3000 Diagnostic Programs
13
McDATA UltraNet Edge 3000 User Guide
13-20
Options={ SINGLE
STOP
Run={
}
Parameters={ 2468
Random
01020304 }
{ BUFFER_BLD
COMPARE_DATA
}
{*ATMC#0:B#3/D#1:PCI#3: D8000000 D8008000 40000000
44000000 }
{ 20
4000000
OC-3
{ BUFFER_MEM
TX/RX_INT
0. Exit Diagnostic
1. Set Options
2. Set Parameters
3. Charm Memory Data Test 15. Charm Basic Line Test
4. Charm Memory Adrs Test 16. Charm Stress Line Test
5. Charm Chip DMA Test
6. Charm Interrupt Test 18. Listen for Cells/PDU's
7. Charm Loopback Test
8. Lpbk Incr Byte Test
9. Lpbk Incr Packet Test 97. Run All P2P
10. Lpbk Increment VC Test 98. Run All Line Tests
11. Charm Port to Port Test 99. Execute All
-> 99
Test 3 - Charm Memory Data Test running...
***** PASSED--- Charm Memory Data Test
failed = 0
Test 4 - Charm Memory Adrs Test running...
***** PASSED--- Charm Memory Adrs Test
failed = 0
Test 5 - Charm Chip DMA Test running...
***** PASSED--- Charm Chip DMA Test
failed = 0
Test 6 - Charm Interrupt Test running...
***** PASSED--- Charm Interrupt Test
failed = 0
Test 7 - Charm Loopback Test running...
***** PASSED--- Charm Loopback Test
failed = 0
Test 8 - Lpbk Incr Byte Test running...
***** PASSED--- Lpbk Incr Byte Test
failed = 0
Test 9 - Lpbk Incr Packet Test running...
***** PASSED--- Lpbk Incr Packet Test
failed = 0
Test 10 - Lpbk Increment VC Test running...
***** PASSED--- Lpbk Increment VC Test
failed = 0
Test 17 - LED Visual Blink Test running...
***** PASSED--- LED Visual Blink Test
passed = 1, failed = 0
0
1 }
Total Errors={ 0 } Tests
2000
00
0011
1
BUFFER_CLR
CHARM Deep PHY Loopback }
INV_CELLS }
12. Charm P2P Incr Byte Test
13. Charm P2P Incr Pkt Test
14. Multi PHYs Test
17. LED Visual Blink Test
77. Debug Utilities
96. Run All Lpbk Tests
52
AAL5
CBR
ADD_CRC_TO_OB
Tests
passed = 1,
passed = 1,
passed = 1,
passed = 1,
passed = 1,
passed = 1,
passed = 1,
passed = 1,
Need help?
Do you have a question about the ULTRANETTM EDGE STORAGE ROUTER 3000 and is the answer not in the manual?
Questions and answers