Group C: Multi-Function Terminal Function Parameters - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

4 Parameter List
4-3-3

Group C: Multi-function Terminal Function Parameters

Parameter
Function name
No.
Multi-function Input 1
C001
Selection
Multi-function Input 2
C002
Selection
Multi-function Input 3
C003
Selection
Multi-function Input 4
C004
Selection
Multi-function Input 5
C005
Selection
Multi-function Input 6
C006
Selection
Multi-function Input 7
C007
Selection
4 - 24
Monitor or data range
00: FW (Forward)
01: RV (Reverse)
02: CF1 (Multi-step speed setting binary 1)
03: CF2 (Multi-step speed setting binary 2)
04: CF3 (Multi-step speed setting binary 3)
05: CF4 (Multi-step speed setting binary 4)
06: JG (Jogging)
07: DB (External DC injection braking)
08: SET (2nd control)
09: 2CH (2-step acceleration/deceleration)
11: FRS (Free-run stop)
12: EXT (External trip)
13: USP (Power recovery restart prevention func-
tion)
14: CS (Commercial switching)
15: SFT (Soft lock)
16: AT (Analog input switching)
18: RS (Reset)
19: TH (PTC thermistor thermal protection, C005
only)
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID disabled)
24: PIDC (PID integral reset)
27: UP (Remote operation accelerated)
28: DWN (Remote operation decelerated)
29: UDC (Remote operation data clear)
31: OPE (Forced operator function)
32: SF1 (Multi-step speed setting bit 1)
33: SF2 (Multi-step speed setting bit 2)
34: SF3 (Multi-step speed setting bit 3)
35: SF4 (Multi-step speed setting bit 4)
36: SF5 (Multi-step speed setting bit 5)
37: SF6 (Multi-step speed setting bit 6)
38: SF7 (Multi-step speed setting bit 7)
39: OLR (Overload limit switching)
40: TL (Torque limit enabled)
41: TRQ1 (Torque limit switching 1)
42: TRQ2 (Torque limit switching 2)
44: BOK (Brake confirmation)
46: LAC (LAD cancel)
47: PCLR (Current position clear)
50: ADD (Set frequency A145 addition)
51: F-TM (Forced terminal block)
52: ATR (Torque command input permission)
53: KHC (Integrated power clear)
56: MI1 (General-purpose input 1)
57: MI2 (General-purpose input 2)
58: MI3 (General-purpose input 3)
59: MI4 (General-purpose input 4)
60: MI5 (General-purpose input 5)
61: MI6 (General-purpose input 6)
62: MI7 (General-purpose input 7)
65: AHD (Analog command held)
66: CP1 (Position command selection 1)
67: CP2 (Position command selection 2)
68: CP3 (Position command selection 3)
69: ORL (Origin search limit signal)
70: ORG (Origin search startup signal)
73: SPD (Speed/Position switching)
81: 485 (Start co-inverter communication)
82: PRG (DriveProgramming start)
83: HLD (Retain output frequency)
84: ROK (Permission of RUN command)
85: EB (Rotation direction detection, C007
only)
86: DISP (Display fixed)
91: PSET (Preset position)
255: no (No allocation)
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Changes
Default
Set
during
data
data
RUN
00
Enabled
(FW)
01
Enabled
(RV)
18
Enabled
(RS)
12
Enabled
(EXT)
02
Enabled
(CF1)
03
Enabled
(CF2)
06
Enabled
(JG)
Unit
Page
P. 5-47
P. 7-18