2.2.7 Connecting the Power
Cord
- When Using a Pedestal
1) Fix the power cord that comes with the machine in
place to the pedestal side using the included cable
clamp (small) [2]; then, connect one end to the
socket.
F-2-61
2) Remove the screw [1] from under the power cord
slot on the pedestal side; then, fit the other end [A]
(hook-shaped) of the included grounding wire [2]
to the pedestal.
Grounding Members
- grounding terminal of power outlet
- iron rod buried 75 cm or more in ground
- terminal wired to specification
F-2-62
2.2.8
0006-4669
1) Open the front cover.
2) Turn the intermediate transfer unit releasing lever
[1] in the direction of the arrow.
3) Remove the waste toner container [1].
4)Remove the screw [1], and remove the dummy
Be sure to store away the removed transfer cleaning
unit. You will need it when executing the following
service mode (for freeing the machine from
condensation as needed by the site of installation):
COPIER>FUNCTION> INSTALL>DRY-RT.
Mounting
Transfer Cleaning Unit
F-2-63
F-2-64
transfer cleaning unit.