Convert First Digit End-of-Dial To
Appears when the Private Group II Permissions and Public Interworking field is y.
Valid entries
0 to 9, #, or blank
Forward Cycle Timer (sec)
Appears when the Incoming Call Type field is mfe.
Valid entries
1 to 255
Group II Called Party Category
Appears when the Outgoing Call Type field is group-ii-mfc and the Use COR for All Group II
Responses field is n. Enter the type of group II signals that should be used on the outgoing
R2-MFC call.
Note:
For India, the ANI can be requested without the Incoming Call Type information.
Note:
Valid entries
user-type
call-type
Usage
Enter the digit used when the incoming initial end-of-ani or
end-of-dial MF signal is converted on a per-switch basis.
Usage
Enter the number of seconds to wait to receive the check
frequency after sending an MFE signal. Communication
Manager drops the call if the time runs out before it
receives check frequency.
Usage
The type of telephone making the call determines the
type of group II signal that the PBX sends (normal =
ordinary telephone set, attendant = attendant console,
data-call = data modules and similar data endpoints).
The dialed digits determine the type of group II signal
that the PBX sends.