Avaya Communication Manager Administrator's Manual page 1603

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Outgoing Seizure (msec)
Appears when the Country field is 15, the Direction field is outgoing or two-way, and the
Trunk Type field is 2-wire-ac, 2-wire-dc, or 3-wire. This timer is sent only to the TN2199 circuit
pack.
Valid entries
20 to 2550 in
increments of 10
Outgoing Seizure Response (sec)
This timer is sent to the TN438B, TN439, TN447, TN458, TN464B (or later), TN465B (or later),
TN767, TN2140, TN2147, TN2184, TN2199, and TN2242 circuit packs.
Valid entries
1 to 255 in
increments of 1
Programmed Dial Pause (msec)
This timer is administrable for all outgoing and two-way trunk groups. This timer works with the
TN464B (or later), TN767, TN458, TN2140, and TN2242 tie circuit packs. All CO circuit packs
that accept administrable timers accept this timer.
Valid entries
100 to 25500 in
increments of
100
Usage
Enter the duration of the outgoing seizure signal.
Usage
Enter the maximum interval that Communication
Manager should wait after sending a seizure signal to
receive seizure acknowledgment from the far-end. If the
acknowledgment is not received in this time, a seizure
failure response is uplinked. For Brazil pulsed E&M
signaling, use 255.
Usage
Set the exact duration of pauses used during
abbreviated dialing, ARS outpulsing, and terminal
dialing operations.
Trunk Group
Issue 1 June 2005
1603