Avaya Communication Manager Administrator's Manual page 1602

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Screen Reference
Outgoing Glare Guard (msec)
This field only appears for outgoing and two-way trunk groups.
Valid entries
100 to 25500 in
increments of
100
Outgoing Last Digit (sec)
This field is only administrable if the Trunk Type field is dis or cont and the trunk group
Direction field is two-way or outgoing. Only TN497 and TN2140 ports receive this timer.
Valid entries
1 to 40 in
increments of 1
Outgoing Rotary Dial Interdigit (msec)
This field only appears when:
1. the trunk group Group Type field is access, aplt, co, diod, dmi-bos, fx, rlt, tandem, or
wats and the Outgoing Dial Type field is rotary.
2. the Group Type field is tie, the Trunk Type field is blank, cont, or dis, and the Outgoing
Dial Type field is rotary.
3. the Group Type field is tie, and the Trunk Type field is tge, tgi, or tru (the Outgoing Dial
Type field does not appear but is implied to be rotary).
Valid entries
150 to 2550 in
increments of 10
1602 Administrator Guide for Avaya Communication Manager
Usage
Enter the minimum interval that must elapse between a
trunk's release from an outgoing call and its seizure for
another outgoing call. This field cannot be blank. This
delay gives the far-end time to release all equipment
after the outgoing trunk is released.
Usage
Enter the maximum time that Communication Manager
will wait for the next digit dialed. After the timer expires,
no more digits are accepted by the circuit pack.
Usage
Enter the minimum time between outpulsed digits on
outgoing rotary trunks.