Avaya Communication Manager Administrator's Manual page 1597

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Flash Length (msec)
This timer is sent to TN436B, TN459B, TN464C (or later), TN465B (or later), (TN753 if Country
is 23), TN2146, TN2147, TN2184, and TN2199 circuit boards.
Valid entries
10 to 2550 in
increments of 10
Glare
This field is only administrable if the Trunk Type field is cont and the trunk group Direction
field is two-way or outgoing. Only TN2140 ports receive this timer.
Valid entries
40 to 100 in
increments of 10
Incoming Dial Guard (msec)
Valid entries
10 to 2550 in
increments of 10
Note:
This timer is never sent to TN429 ports.
Note:
Usage
Enter the duration of a flash signal generated toward the
central office.
Usage
Enter the minimum acceptable interval (in msec)
between the moment your server running
Communication Manager sends an outgoing seizure
and the moment it receives a seizure acknowledgment.
If acknowledgment is received before the timer expires,
glare is assumed.
Usage
Enter the minimum acceptable interval between the
detection of an incoming seizure and the acceptance of
the first digit. Communication Manager will not accept
digits before this timer expires.
Trunk Group
Issue 1 June 2005