Marginal Threshold - -Dev - 404 Hz Loss
Valid entries
0 to 9
Marginal Threshold - +Dev - 404 Hz Loss
Valid entries
0 to 9
Marginal Threshold - -Dev - 2804 Hz
Valid entries
0 to 9
Marginal Threshold - +Dev - 2804 Hz
Valid entries
0 to 9
Usage
Enter the maximum negative deviation of measured
loss at 404 Hz from the 1004 Hz test tone noise level (in
dB) allowed before reporting a trunk as out of tolerance.
Smaller dB values are more restrictive.
Usage
Enter the maximum positive deviation of measured loss
at 404 Hz from the 1004 Hz test tone loss level (in dB)
allowed before reporting a trunk as out of tolerance.
Smaller dB values are more restrictive.
Usage
Enter the maximum negative deviation of measured
loss at 2804 Hz from the 1004 Hz test tone loss level
(in dB) allowed before reporting a trunk as out of
tolerance. Smaller dB values are more restrictive.
Usage
Enter the maximum positive deviation of measured
loss at 2804 Hz from the 1004 Hz test tone loss level
(in dB) allowed before reporting a trunk as out of
tolerance. Smaller dB values are more restrictive.