Normal Outgoing Seize Send (msec)
This field appears only if the Trunk Type field is dis and the trunk group Direction field is
two-way or outgoing. Only TN2140 ports receive this timer.
Valid entries
10 to 990 in
increments of 10
Outgoing Dial Guard (msec)
Valid entries
100 to 25500 in
increments of
100
Outgoing Disconnect (msec)
Valid entries
50 to 2550 in
increments of 10
1600 Administrator Guide for Avaya Communication Manager
Usage
Enter the duration of the signal your server running
Communication Manager sends for an outgoing seizure.
Usage
Enter the minimum interval between seizure
acknowledgment of a trunk and the outpulsing of digits.
This field cannot be blank. For trunks that do not provide
seizure acknowledgment, the timer specifies the
minimum time between seizure and the outpulsing of
digits. Any digit the caller dials after they lift the receiver,
but before the timer expires, is not outpulsed until the
timer expires.
Usage
Enter the minimum valid duration of a disconnect signal
for an outgoing call. Communication Manager will not
recognize shorter disconnect signals. This field cannot
be blank. This timer begins timing when a disconnect
signal is detected on an outgoing call and resets when
the signal is no longer detected. If the timer expires, the
trunk drops. For Brazil pulsed E&M signaling, use 600.