Ethernet Ring Protection Commands
erp-ring rpl-node
Configures a switch as a Ring Protection Link (RPL) node. This command also identifies the ERP port as
an RPL connection port. The RPL remains blocked to prevent loops within the ERP ring.
erp-ring ring_id rpl-node {port slot/port | linkagg agg_num}
no erp-ring ring_id rpl-node
Syntax Definitions
ring_id
slot/port
agg_num
Defaults
NA
Platforms Supported
OmniSwitch 10K
Usage Guidelines
•
Use the no form of this command to remove the RPL designation for the specified ring.
•
The RPL node can be configured only when the ring is disabled; RPL configuration applied to the ring
while it is enabled will be rejected.
•
The specified ERP ring ID must already exist in the switch configuration.
•
This command applies only to ERP ring ports; ports not configured as ERP ring ports are not eligible
to become RPL ports.
•
Only one of the two ring ports configured for the switch can be designated as an RPL node port.
Examples
-> erp-ring 1 rpl-node port 2/1
-> erp-ring 2 rpl-node linkagg 2
-> no erp-ring 2 rpl-node
Release History
Release 7.1.1; command was introduced.
OmniSwitch CLI Reference Guide
An existing ERP ring ID number. The valid range is 1- 2147483647.
The slot number for the module and the physical port number on that
module.
The link aggregate ID number.
March 2011
erp-ring rpl-node
page 8-5