erp-ring rpl-node

Configures a switch as a Ring Protection Link (RPL) node. This command also identifies the ERP port as
an RPL connection port. The RPL remains blocked to prevent loops within the ERP ring.
erp-ring ring_id rpl-node {port slot/port | linkagg agg_num}
no erp-ring ring_id rpl-node
Syntax Definitions
ring_id
slot/port
agg_num
Defaults
NA
Platforms Supported
OmniSwitch 10K
Usage Guidelines
Use the no form of this command to remove the RPL designation for the specified ring.
The RPL node can be configured only when the ring is disabled; RPL configuration applied to the ring
while it is enabled will be rejected.
The specified ERP ring ID must already exist in the switch configuration.
This command applies only to ERP ring ports; ports not configured as ERP ring ports are not eligible
to become RPL ports.
Only one of the two ring ports configured for the switch can be designated as an RPL node port.
Examples
-> erp-ring 1 rpl-node port 2/1
-> erp-ring 2 rpl-node linkagg 2
-> no erp-ring 2 rpl-node