Show Multi-Chassis Vf-Link Member-Port - Alcatel-Lucent 060321-10, Rev. B Cli Reference Manual

Omniswitch series
Table of Contents

Advertisement

show multi-chassis vf-link member-port

show multi-chassis vf-link member-port
Displays detailed information about the configured and operational parameters related to the virtual fabric
link member ports on the switch.
show multi-chassis vf-link member-port [slot/port]
Syntax Definitions
slot/port
Defaults
NA
Platforms Supported
OmniSwitch 10K
Usage Guidelines
NA
Examples
-> show multi-chassis vf-link member-port
VFLink ID
Slot/Port
----------+-----------+---------+------------
0
1/1
0
1/2
0
1/17
0
1/18
-> show multi-chassis vf-link member-port 3/1
VFLink ID
Slot/Port
----------+-----------+---------+------------
0
1/2
Output fields are defined here:
output definitions
VFLink ID
Slot/Port
page 7-28
Specify the slot number for the module and the physical port number on
that module (e.g., 3/1 specifies port 1 on slot 3).
Oper
Is Primary
Up
No
Up
Yes
Up
No
Up
No
Oper
Is Primary
Up
Yes
Virtual Fabric Link identifier. Currently a single virtual fabric link with
identifier equalt to zero is supported.
The slot/port that defines each of the physical ports that are members of
the virtual fabric link.
Multi-Chassis Commands
OmniSwitch CLI Reference Guide
March 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 10k

Table of Contents