4.2.3.Replacement Procedure (For Hard Disk Failures Not Causing Non-Responsiveness) - Fujitsu PRIMEQUEST 1000 Series User Manual

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

From the above example, you can confirm that the Fault LED of slot 2 of
ioc0 is on, so sdc was surveyed in that slot.
2) Turn off the Fault LED by executing the following disk management
command.
# /opt/fujitsu/SVmco/bin/diskctrl -o ioc0/2
The Fault LED goes out.
Display the status by executing the disk management command.
You can confirm that "none" is displayed as the device name of slot 2 of
ioc0 and the slot is empty.
# /opt/fujitsu/SVmco/bin/diskctrl -l
ioc0
0 /dev/sda
1 /dev/sdb
2 none
3 /dev/sdd
4.2.3.Replacement procedure (for hard disk
failures not causing non-responsiveness)
Fault LED-Off
Fault LED-Off
Fault LED-Off
SVmco User Guidel
142

Hide quick links: