(R/M/T/S)
18607
SV RAID:%2 Device error (Logical drive is not ready)
Meaning:
The logical drive is not in the ready state.
Corrective action:
Check the current state of the logical drive. If it is in the critical state, replace the
faulty hard disk, and perform a rebuild.
If it is in the offline state, reconfigure the array. Restore data from a backup.
Severity:
Warning
Action:
(R/M/T/S)
18608
SV RAID:%2 Adapter error (Adapter has been replaced during reboot)
vendor-id=1000 device-id=%d revision=%r
Meaning:
The adapter was replaced during a reboot.
%2: Device name
%d: (Example) 0079
SVmco User Guidel