7.2.12.ServerView RAID messages [Linux]
This section lists ServerView RAID-related messages.
18500
SV RAID:%2 Adapter error (BBU temperature out of range) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
An abnormal battery temperature was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView RAID. If a fan failure occurred, take
corrective action for the target unit. For details on how to check the status in
ServerView RAID, see the ServerView Suite ServerView RAID Management
User Manual.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.
Severity:
Error
Action:
(R/M/T/S)
SVmco User Guidel