5 (Illegal Request): Examine the software.
6 (Unit Attention): This is notification information from various devices. (e.g.,
reset status, RAID degradation if applicable)
7 (Data Protect): Check the Write Protect status.
8 (Blank Check): Check tape and other operations.
b (Aborted Command): Investigate problems in the SCSI bus and FC
transmission paths.
Severity:
Warning
Action:
(R/M/T/S)
14140
sd:sd[a-z]* Device error (Use a kernel compiled with support for large
block devices) vendor=%v model=%m serial-no=%ser
Meaning:
A device error occurred. The disk size is too large.
%v: (Example) FUJITSU
%m: (Example) MAP3367NC
%ser: (Example) 01234567
Corrective action:
If a single drive is used, replace the disk. If an ETERNUS machine is used,
examine it. Alternatively, use a kernel that supports the disk capacity.