Fujitsu PRIMEQUEST 1000 Series User Manual page 664

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

Check the sense key included in the message. Take corrective action as
described below, according to the character string of the sense key.
For "No Sense," "Recovered Error," or "Unit Attention":
>> If the error occurred alone, no action is necessary. If the error has
occurred repeatedly, collect the data for investigation (dump or fjsnap),
and contact your sales representative or a field engineer.
For "Medium Error":
>> Replace the disk or tape.
For "Blank Check":
>> Check the read and write operations of the disk or tape. If there is no
problem in operations, collect the data for investigation (dump or fjsnap),
and contact your sales representative or a field engineer.
Other
>> Collect the data for investigation (dump or fjsnap). Contact your sales
representative or a field engineer.
Severity:
Warning
Action:
(R/M/T/S)
14166
scsi:%h:%c:%i:%l Software error (event eaten due to OOM)
Meaning:
OOM Killer destroyed the process.
SVmco User Guidel