Fujitsu PRIMEQUEST 1000 Series User Manual page 482

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

13018
mptscsih:iocx Adapter error (Unexpected doorbell active) vendor-id=1000
device-id=%d revision=%r
Meaning:
An unexpected active state of the adapter was detected.
%d: (Example) 0030
%r: Numerical value (1 to 3 digits)
Corrective action:
The HBA must be replaced. If the error keeps recurring, contact your sales
representative or a field engineer.
Severity:
Warning
Action:
(R/M/T/S)
13019
mptscsih:iocx Adapter error (IOC is in FAULT state) vendor-id=1000
device-id=%d revision=%r
Meaning:
The adapter state changed to fault.
%d: (Example) 0030
SVmco User Guidel
474

Hide quick links: